Testanforderungen UL ..."/>

Sinus-Schwingschwingungs-Vibrations-Schüttelsystem ISO ASTM IEC des Schwingungs-Schüttelsystems

Sinus-Schwingschwingungs-Vibrations-Schüttelsystem ISO ASTM IEC des Schwingungs-Schüttelsystems

Norm
GB/T 31486-2015 <Electrical performance requirements and test methods for traction battery of electric vehicle> Test requirements
UL 1642:2012 < Norm for Lithium batteries>
UL 2054: 2012 < Household and Commercial Batteries>
UN38.3(2012) <Part 3: proposal for dangerous goods transport - test and standard manual>
IEC62133-2:2017 < Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications-Parts 2: Lithium systems>
 

Beschreibung

Sine Random Shock Vibrations-Prüfsystem ISO ASTM IEC Of Vibrations-Rüttler System


Einleitung

JOEO vibration test system is used to simulate various environmental conditions, especially the vibration and shock that a product or part may experience during its life cycle, and can be used for various test types, including sinusoidal scanning, random vibration, shock pulse, resonance search, etc. By simulating real conditions in a controlled environment, these shakers can help engineers identify potential weaknesses in designs and make improvements to improve product durability and performance. JOEO vibration test system are commonly used in industries such as automotive, aerospace, defense and consumer electronics, and play a vital role in evaluating product durability and reliability.

JOEO vibration shaker system, adopted the 'double-magnetic circuit structure',' self-generated skeleton action circles', 'Airborne Support’ and 'roller bearings and linear guidance', 'trunnion isolation’ advanced modern technology and special technology, can be completed in X,Y,Z three-axis sinusoidal shaker testing and broadband random vibration tests, to be completed by the classical (half - sine, trapezoidal, saw tooth wave) pulse and shock response spectrum test.  

Funktionen:

  • Gut gestaltetes zirkuläres Leistungsskelett mit einer hohen axialen Resonanzfrequenz. 
  • Zwei magnetische Schaltkreise, geringe magnetische Streuung, kompakte und vernünftige Struktur.
  • Kipprollenlager, gerade Stangenausrichtung und Einlass, komplexe Ausrichtungssteifigkeit, exzentrische Lagerkapazität ist stark.
  • Das Isolationsfundament für den Ohrrahmen ist für den Hormonkonsum konzipiert und einfach zu installieren und zu bewegen. Die fortschrittliche Wickeltechnologie gewährleistet die hohe Zuverlässigkeit des dynamischen Zyklus des Systems.
  • Neues Luftkanaldesign, verbessert den Kühleffekt.
  • Das Lager mit geringer statischer und dynamischer Steifigkeit verbessert die Tragfähigkeit des Rütteltisches und verbessert die Niederfrequenzleistung.
Customised head expanders and fixtures About vibration shaker system



Norm export packing

Erforderliches Steuerungssystem oder Oszillator:

Neben dem kompakten Schwingungsgenerator und der Leistungsverstärkereinheit kann für Ihre Anwendung ein Schwingungskontrollsystem oder ein Funktionsgenerator, ein Beschleunigungsmesser und ein Ladungsverstärker erforderlich sein.
Für die Endstufe ist optional ein Oszillator erhältlich.
As for details, please contact our sales department, the have professional suggestion for those shaker test equipment. 

Parameter 

Systemmodell Sinus-/Zufallskraft (kN) Stoßkraft (kN) Frequenzbereich (Sinus) (Hz) Frequenzbereich (zufällig) (Hz) Max. Beschleunigung (Sinus) (g) Max. Beschleunigung (zufällig) (g) Max. Velocity  (m/s) Max. Verschiebung (mm) Max. Belastung (kg) Masse des beweglichen Teils (kg) Durchmesser des Ankers (mm) Resonance Point  (Hz) Isolations-Airbag-Resonanzfrequenz (Hz) Gewicht (kg)
ES-1-150  1/1 2 3-4500 3-4500 50 30 2 25 70 2 Φ150 3900 3 395
ES-2-150  2/2 4 3-4500 3-4500 100 60 2 40 70 2 Φ150 3900 3 395
ES-3-150  3/3 6 3-3500 3-3500 100 60 2 25 120 3 Φ150 2900 3 480
ES-6-230  6/6 12 3-3500 3-3500 100 60 2 51 300 6 Φ230 3400 3 590
ES-10-240  10/10 20 3-3200 3-3200 100 60 2 51 300 10 Φ240 2700 2.5 900
ES-10G-240  10/10 20 3-3000 3-3000 85 50 2 76 300 13 Φ240 2500 2.5 1000
ES-10H-240  10/10 20 3-3000 3-3000 100 60 1.8 51 300 10 Φ240 3300 2.5 900
ES-20-320 20/20 40 3-3000 3-3000 100 60 2 51 300 20 Φ320 2800 2.5 1700
ES-20G-340 20/20 40 3-3000 3-3000 80 48 2 76 300 25 Φ340 2700 2.5 1700
ES-30-370 30/30 60 3-2800 3-2800 100 60 2 51 500 30 Φ370 2500 2.5 2490
ES-40-370 40/40 80 3-2800 3-2800 130 78 2 51 500 40 Φ370 2500 2.5 2490
ES-30G-370 30/30 60 3-2600 3-2600 85 51 2.4 100 500 35 Φ370 2400 2.5 2540
ES-40G-370 40/40 80 3-2600 3-2600 100 60 2.4 100 500 35 Φ370 2400 2.5 2540
ES-40-445 40/40 80 3-2700 3-2700 80 48 2 51 800 50 Φ445 2400 2.5 4500
ES-50-445 50/50 100 3-2700 3-2700 100 60 2 51 800 50 Φ445 2400 2.5 4500
ES-60-445 60/60 120 3-2700 3-2700 100 60 2 51 800 50 Φ445 2400 2.5 4500
ES-50G-445 50/50 100 3-2600 3-2600 90 54 2 76 800 55 Φ445 2300 2.5 4500
ES-60G-445 60/60 120 3-2600 3-2600 100 60 2 76 800 55 Φ445 2300 2.5 4500
ES-50G-445 50/50 100 3-2500 3-2500 85 51 2 100 800 60 Φ445 2200 2.5 4500
ES-60G-445 60/60 120 3-2500 3-2500 100 60 2 100 800 60 Φ445 2200 2.5 4500
ES-70G-480 70/70 140 3-2700 3-2700 100 60 2 76 1000 70 Φ480 2200 2.5 4500


Technische Parameter der horizontalen Bank

Modell Größe der Bank (mm) Frequenzbereich (Hz) Gewicht der beweglichen Teile (kg)
Nr. H0303 300x300 cmx22 cm 5-1000 6.6
300x300 cmx26 cm 5-1500 7.8
300x300 cmx30 cm 5-2000 9.0
Nr. H0404 400x400 cmx22 cm 5-1000 11.2
400x400 cmx26 cm 5-1400 13.2
400x400 cmx30 cm 5-2000 16.0
Nr. H0505 500x500 cmx25 cm 5-1000 19.3
500x500 cmx30 cm 5-1500 23.1
500x500 cmx35 cm 5-2000 27.0
Nr. H0606 600x600 cmx25 cm 5-1000 27.5
600x600 cmx30 cm 5-1200 33.0
600x600 cmx40 cm 5-2000 45.0
Nr. H0707 700x700x25 cm 5-800 36.8
700x700x30 cm 5-1000 44.2
700x700x35 cm 5-1500 52.0
Nr. H0808 800x800 cmx30 cm 5-1000 57.7
800x800 cmx40 cm 5-1500 76.9
800x800 cmx45 cm 5-2000 86.5
Nr. H1010 1000x1000 cmx30 cm 5-1000 89.1
1000x1000 cmx40 cm 5-1300 118.8
1000x1000 cmx50 cm 5-1500 147.0
Nr. H1212 1200x1200 cmx30 cm 5-800 126.0
1200x1200 cmx40 cm 5-1100 168.0
1200x1200 cmx50 cm 5-1400 210.0

Technische Parameter der vertikalen Bank

Modell Gewicht (kg) Max. Frequenz (Hz) Größe der Bank (mm)
V300 (Magnesium) 10 2000 Φ300
V400 (Magnesium) 16 2000 Φ400
V500 (Magnesium) 25 1500 Φ500
V600 (Magnesium) 35 1000 Φ600
Nr. V0303 15 2000 300x300 cm
Nr. V0404 22 1500 400x400 cm
Nr. V0505 30 500 500x500 cm
Nr. V0606 58 350 600x600 cm
Nr. V0808 140 350 800x800 cm
Nr. V1010 180 350 1000x1000 cm
V1212 (Magnesium) 250 350 1200x1200 cm
V1212 (Runde Bank) 220 350 Φ1200